Analytical Balance: Uses and How to Use It

Home › Laboratory Equipment

Laboratory equipment guide

Analytical Balance: Uses and How to Use It

An analytical balance is a highly sensitive electronic balance with a readability of 0.1 mg (0.0001 g) or better, enclosed by glass doors that block air currents. It is used to weigh substances for quantitative analysis and standard solutions.

Parts of a analytical balance

What is a analytical balance used for?

  • Weighing substances for standard solutions and quantitative analysis.
  • Determining moisture or ash content by mass difference.
  • Checking volumetric glassware by gravimetric calibration.

Parts of a analytical balance

  1. 1Display – shows mass to 0.0001 g
  2. 2Glass draft shield – blocks air currents
  3. 3Weighing pan – holds the container and sample
  4. 4Tare key and levelling feet – zero the container and level the balance
Parts of a analytical balance: 1) Display, 2) Glass draft shield, 3) Weighing pan, 4) Tare key and levelling feet.
Parts of a analytical balance: 1) Display, 2) Glass draft shield, 3) Weighing pan, 4) Tare key and levelling feet.

How to use a analytical balance

Analytical Balance – Step 1: Check it is level and warmed up
Step 1

Check it is level and warmed up

Check the level bubble is centred in its circle (1); if not, adjust the levelling feet. Switch the balance on at least 30 minutes before use so it stabilises.

Analytical Balance – Step 2: Place the container, close the doors, press tare
Step 2

Place the container, close the doors, press tare

Place the container (watch glass, weighing paper or weighing bottle) in the centre of the pan, close the doors and press tare (1) until the display shows 0.0000 g.

Analytical Balance – Step 3: Add the substance with a spatula
Step 3

Add the substance with a spatula

Open a side door and add the substance a little at a time with a spatula (1). Do not spill onto the pan; clean up immediately if you do.

Analytical Balance – Step 4: Close the doors, wait for stability, then record
Step 4

Close the doors, wait for stability, then record

Close all doors and wait for the stability indicator before recording the mass (1). Samples must be at room temperature; warm items create air currents and drifting readings.

Common mistakes

  • Weighing substances directly on the pan without a container.
  • Handling weighing containers with bare fingers: skin oil and moisture add mass. Use tweezers or gloves.

Care and safety

  • Brush the pan and weighing chamber clean after every use.
  • Keep it on a sturdy, vibration-free bench away from doors, air conditioning and direct sunlight.

SOP for using a analytical balance

A summary of the standard operating procedure (SOP) for a analytical balance that your laboratory can adapt. Each step is explained in the how-to section above.

1Protective equipment

  • A lab coat and powder-free gloves.
  • A mask or a ventilated weighing enclosure for toxic powders.

2Before use

  • The balance is level (bubble centred) and has been on for at least 30 minutes.
  • The pan and chamber are clean; the doors are closed.
  • Run an internal or external calibration as scheduled or after the balance is moved.
  • Samples and containers are at room temperature.

4After use

  • Remove the container, brush away spills and close the doors.
  • Leave it on standby if used often, so it does not need warming up again.
  • Record use in the balance log.

5Verification & calibration

  • Daily check with a standard weight (e.g. class E2 or F1) near the usual load; record the result.
  • Periodic repeatability and eccentricity tests, and calibration by an accredited lab at least once a year.

6Emergencies

  • Spill inside the balance: switch off and clean with a brush and damp cloth according to the SDS; never spray liquids.
  • Chemical on skin or in eyes: rinse with running water for at least 15 minutes (eyewash or safety shower), then report to the lab supervisor.

A print-ready version with purpose, scope, illustrated procedure, verification and sign-off boxes. Fill in your own document number and effective date.

Download the SOP (PDF, A4)

Types and sizes

Analytical balances usually weigh 120–220 g with 0.1 mg readability; semi-micro balances read 0.01 mg and micro balances 0.001 mg for tiny samples. Precision balances (0.01–0.001 g) are used for rougher weighing. Internal calibration is convenient in busy labs.

Analytical Balance at AMI Scientific

Examples of analytical balance available in our store. Prices exclude VAT.

AMI Scientific supplies laboratory glassware, instruments and chemicals with tax invoices and delivery across Indonesia.

Frequently asked questions

How accurate is an analytical balance?

Typically 0.1 mg or 0.0001 g. Semi-micro balances reach 0.01 mg.

Why must the balance doors be closed?

Even slight air movement changes the reading at 0.1 mg resolution. The glass doors block those currents.