Acid–Base Indicators: Litmus Paper, Universal Indicator, PP and pH Ranges

An acid–base indicator is a substance whose colour changes with the pH of a solution, so it shows whether the solution is acidic, neutral or basic. The most common are litmus paper (red and blue), universal indicator, phenolphthalein (PP), methyl orange and bromothymol blue. The pH range over which an indicator changes colour is its transition range. Move the simulator below to see each indicator's colour at a given pH.

pH indicator colour simulator

pH 7,0
02468101214

Colours are approximations for learning. Universal indicator colours follow each brand's chart; phenolphthalein turns colourless again at very high pH (about 13 and above).

Litmus paper: how to use it and what it shows

Litmus paper is paper soaked in litmus dye and comes as red litmus and blue litmus. Dip the tip into the solution, or touch it with a drop on a stirring rod, and watch the colour. Litmus only distinguishes acids from bases; to find the pH value, use universal indicator or a pH meter.

Solution Red litmus Blue litmus
Acidic (pH < 7) stays red turns red
Neutral (pH 7) stays red stays blue
Basic (pH > 7) turns blue stays blue

Litmus changes over roughly pH 4.5–8.3, so very weakly acidic or basic solutions may not change the paper. Keep litmus paper in a closed container, away from acid or ammonia vapour.

Universal indicator

Universal indicator is a mixture of several indicators, so its colour changes step by step over pH 1–14: red for strong acids, orange and yellow for weak acids, green around neutral, then blue to violet for bases. It comes as paper or solution. Add the test solution to the paper (or a few drops of indicator to the solution), wait as instructed, and match the colour with the chart on the pack to read the pH.

Available: Universal Indicator Solution, 1 L – Smartlab A-1551.

Phenolphthalein (PP) indicator

PP indicator is phenolphthalein (C20H14O4). It is colourless in acidic and neutral solutions and turns pink at about pH 8.2, magenta above pH 10. Because it changes in the basic range, PP is the right indicator for titrating a weak acid (e.g. acetic acid/vinegar) with a strong base (NaOH), and it is also common for strong acid–strong base titrations. It is usually prepared as a 1% solution in ethanol. Phenolphthalein carries a health-hazard symbol; see the phenolphthalein MSDS.

Indicator transition range table

Indicator pH range Colour below range Colour above range Product
Thymol blue (acid range) 1.2 – 2.8 red yellow Thymol Blue (TCI T0235)
Thymol Blue, 25 g (Smartlab)
Methyl orange 3.1 – 4.4 red yellow Methyl Orange (TCI M0489)
Methyl Orange 25 GR (Smartlab)
Bromocresol green 3.8 – 5.4 yellow blue Bromocresol Green (TCI B0578)
Bromocresol Green, 10 g (Smartlab)
Methyl red 4.4 – 6.2 red yellow –
Litmus 4.5 – 8.3 red blue Litmus Solution 0.1 N (0.02 M), 1 L (Smartlab)
Litmus Granular, 500 g (Smartlab)
Bromothymol blue (BTB) 6.0 – 7.6 yellow blue Bromothymol Blue (TCI B0657)
Bromothymol Blue, 25 g (Smartlab)
Thymol blue (base range) 8.0 – 9.6 yellow blue Thymol Blue (TCI T0235)
Phenolphthalein (PP) 8.2 – 10.0 colourless pink to magenta Phenolphthalein, 25 g (Smartlab)

Range limits can differ by about 0.2 pH units between sources and depend on temperature and solvent. For official analysis, follow your standard method.

Choosing an indicator for acid–base titration

Choose an indicator whose range covers the pH at the equivalence point:

Titration type Equivalence-point pH Suitable indicator
Strong acid – strong base (HCl – NaOH) ± 7 BTB, phenolphthalein or methyl red
Weak acid – strong base (CH3COOH – NaOH) > 7 (about 8–9) Phenolphthalein (PP)
Strong acid – weak base (HCl – NH3) < 7 (about 5) Methyl red or methyl orange

Calculate the concentration from your titration with the titration calculator.

Natural indicators

Some natural materials also change colour with pH because they contain pigments such as anthocyanins. Red cabbage is red in acid, purple near neutral, and green to yellow in strong base. Turmeric is yellow in acidic and neutral solutions and reddish-brown in base. Hibiscus and butterfly pea flowers are also used in school practicals. Natural indicators suit teaching but are less sharp and not standardised for analysis.

Need an exact pH value? Use a pH meter

Indicators give an estimate, typically to about one pH unit. For 0.01 pH precision, e.g. in water, food or research quality control, use a pH meter calibrated with buffer solutions. See pH meter prices and the pH formula and calculator.

Frequently asked questions

What is an acid–base indicator?

A substance whose colour changes with pH, showing whether a solution is acidic, neutral or basic. Examples are litmus paper, universal indicator, phenolphthalein and methyl orange.

What colour is litmus in acids and bases?

In acid, blue litmus turns red and red litmus stays red. In base, red litmus turns blue and blue litmus stays blue. In a neutral solution neither changes.

What is an indicator's transition range?

The pH range over which its colour changes, e.g. about pH 8.2–10.0 for phenolphthalein and about 3.1–4.4 for methyl orange.

What colour is phenolphthalein in acid and base?

Colourless in acidic and neutral solutions, pink to magenta in bases above about pH 8.2.

What is the difference between universal indicator and litmus?

Litmus only shows acid or base. Universal indicator gives a different colour for each pH from 1 to 14, so the pH value can be estimated.

Which indicator is used for a weak acid–strong base titration?

Phenolphthalein (PP), because the equivalence point is in the basic range, about pH 8–9.

Browse laboratory chemicals Ask via WhatsApp