TCI
Couldn't load pickup availability
Description
Fluoranthene supplied under TCI catalogue code F0016 is a polycyclic aromatic hydrocarbon built from a naphthalene unit and a benzene unit joined through a five-membered ring. This fused arrangement places it among the most frequently encountered PAH compounds formed during incomplete combustion, whether from motor vehicles, biomass burning, or industrial processes. In the laboratory, fluoranthene serves as an important standard compound for environmental analysis, because its presence in air, soil, water, and sediment is routinely monitored as an indicator of polycyclic aromatic hydrocarbon pollution across a wide range of sample matrices.
The property that makes this compound a preferred choice is its extensively conjugated aromatic system, which produces strong fluorescence together with a characteristic ultraviolet absorption profile. Because of this behaviour, the compound is readily detected at low concentration levels using either fluorescence detectors or mass spectrometry. Its chemical stability is high and its boiling point lies far above room temperature, so the solid material can be stored for long periods without meaningful change and is well suited for preparation of stable stock solutions. Good solubility in non-polar organic solvents further simplifies the preparation of standard series for calibrating analytical instruments.
Indonesian laboratories typically use this material as a reference compound within environmental monitoring and analytical chemistry programmes, where PAH content in air, water, soil, and sediment samples must be quantified reliably. It is equally suited to method development and instrument verification work, since a well-characterised, stable PAH standard allows chromatographic and spectroscopic systems to be calibrated consistently. Its role as a non-heterocyclic building block also supports synthetic and materials-oriented research activities.
Laboratory Applications
- Environmental PAH monitoring: fluoranthene is one of the most commonly detected combustion-derived PAH compounds, making it an essential reference standard when quantifying hydrocarbon pollution in air, soil, water, and sediment samples.
- Calibration standard preparation: good solubility in non-polar organic solvents allows analysts to prepare stable stock solutions and accurate dilution series for routine calibration of analytical instrumentation.
- Fluorescence detection methods: the extensively conjugated aromatic system produces strong fluorescence, so the compound is easily detected at very low concentration levels using fluorescence detectors in chromatographic systems.
- Mass spectrometry and ultraviolet analysis: characteristic ultraviolet absorption and reliable response under mass spectrometric detection make this compound suitable for confirming identity and quantifying PAH residues in complex samples.
- Non-heterocyclic building block applications: as a stable polycyclic aromatic framework, fluoranthene serves synthetic and materials research where an extended conjugated carbon skeleton is required as a starting structure.
Specifications
- Brand: TCI (Tokyo Chemical Industry), catalogue code F0016
- CAS Number: 206-44-0
- Category: Chemistry > Building Blocks > Non-Heterocyclic Building Blocks
- Pack sizes: available in standard TCI catalogue packaging; please confirm the required pack size when ordering
- Physical form: solid material at room temperature
- Storage note: keep in a tightly closed container, protected from light, in a cool and well-ventilated area
Handling and Storage
Store fluoranthene in its original tightly closed container, kept in a cool, dry, and well-ventilated area away from direct sunlight and sources of heat or ignition. Amber glass or otherwise light-protected containers are appropriate for both the solid material and any prepared stock solutions, since prolonged light exposure is best avoided for polycyclic aromatic compounds. Handle the substance inside a fume hood and wear standard laboratory personal protective equipment, including gloves, safety glasses, and a laboratory coat, to prevent skin contact and inhalation of dust. Avoid generating airborne particles when weighing. Keep the material separated from strong oxidising agents, label all prepared solutions clearly, and dispose of residues and contaminated consumables through the laboratory's chemical waste procedures. Consult the manufacturer's safety data sheet before first use.
Dokumen Keamanan & Mutu
Spesifik per batch produksi — diterbitkan dan dikirim bersama barang sesuai nomor lot yang Anda terima.
Contoh CoA segera tersedia.Share

Produk Terkait
-
9-([1,1'-Biphenyl]-4-yl)anthracene TCI B5717
Regular price From Rp 1.358.700,00Regular priceSale price From Rp 1.358.700,00 -
4-(3-Buten-1-yl)-4'-methylbiphenyl TCI B5872
Regular price From Rp 2.333.100,00Regular priceSale price From Rp 2.333.100,00 -
4,4'-Bis(trans-4-propylcyclohexyl)biphenyl TCI B5881
Regular price Rp 1.741.950,00Regular priceSale price Rp 1.741.950,00Sold out -
Biphenylene TCI B6284
Regular price From Rp 3.099.600,00Regular priceSale price From Rp 3.099.600,00 -
Benzo[k]fluoranthene TCI B6317
Regular price From Rp 3.541.650,00Regular priceSale price From Rp 3.541.650,00 -
Benzo[j]fluoranthene TCI B6424
Regular price From Rp 3.246.600,00Regular priceSale price From Rp 3.246.600,00 -
Benzo[c]phenanthrene TCI B6541
Regular price From Rp 2.038.050,00Regular priceSale price From Rp 2.038.050,00 -
1-Benzyl-4-methylbenzene TCI B6623
Regular price From Rp 2.657.550,00Regular priceSale price From Rp 2.657.550,00